MIL-PRF-49080D
Reqt Para.
Test Para.
Measurement
Input and Output Voltage
Ripple Voltage
Low pressure (altitude). The power supply shall operate up to 15,000 feet above
3.8.3
sea level and shall withstand up to 40,000 feet above sea level. Before, during, and after testing as
specified in 4.6.3, the power supply shall meet full specification performance for the following
measurements:
Measurement
Reqt Para.
Test Para.
Input and Output Voltage
Ripple Voltage
Immersion. Before and after testing as specified in 4.6.4, the power supply shall
3.8.4
show no evidence of leakage and meet full specification performance for the following
measurements:
Reqt Para.
Test Para.
Measurement
Input and Output Voltage
Ripple Voltage
Vibration and ballistic shock. The power supply shall experience no deleterious
3.8.5
tested. Full specification performance for the following measurements shall be met before and after
testing:
Reqt Para.
Test Para.
Measurement
Input and Output Voltage
Ripple Voltage
Fungus. The power supply, when tested, shall show no more than six minute
3.8.6
unrelated spots, each no greater than 0.015 square inch in area, of sparse microbial growth (see
sporulation (see 6.5.7) on or within each cubic foot, or fraction thereof, of power supply assembly
volume. Isolated instances of partial tubular germination (see 6.5.8) shall not be included in this
evaluation.
Sand and dust. The power supply shall operate in its normal operational
3.8.7
configuration, while exposed to blowing dust and sand environments as tested in 4.6.9. Failure of
the power supply to maintain the required output during testing shall constitute a failure of this test.
Before and after testing as specified, the power supply shall meet full specification performance for
the following measurements:
Measurement
Reqt Para.
Test Para.
Input and Output Voltage
Ripple Voltage
9